DKN-RFT-1612 is the 1600 mm wide mesh belt model in the Kunning Cryo mesh belt freezer product line: mesh belt width 1600 mm, mesh belt length 12 m, with compressor refrigeration as the cold source. Material is spread onto the stainless steel mesh belt from the infeed end, travels continuously through the low-temperature zone with the mesh belt to complete freezing, and then exits from the discharge end. It is suitable for aquatic products, meat and poultry, prepared dishes and other production lines requiring continuous feeding and stable rhythm. The equipment does not require a liquid nitrogen storage tank or low-temperature piping; it can operate once connected to power on site and with condensation and heat dissipation conditions in place; working temperature, cooling capacity and freezing cycle are configured according to customer materials and capacity, confirmed at the time of order.

Mesh belt freezer continuous conveying section

Technical Parameters

Item Parameter
Product Model DKN-RFT-1612
Product Line Mesh belt freezer (compressor refrigeration)
Mesh Belt Size 1600 mm (width) × 12000 mm (length)
Structure Type Continuous mesh belt conveying, material passes through low-temperature zone with the mesh belt
Cold Source Compressor refrigeration (mechanical refrigeration)
Working Temperature Confirmed per order (configured according to material and capacity)
Freezing Cycle Confirmed per order (mesh belt variable frequency speed control)
Discharge Core Temperature Confirmed per order (quick freezing conditions calculated at core temperature below -18℃)
Total Power Confirmed per order
Condensation Method Confirmed according to site conditions and order (air-cooled / water-cooled / evaporative cooling)
Refrigerant Confirmed per order
Power Supply Specification 380V/50Hz

Mesh belt size is the effective conveying surface dimension. Actual capacity is related to material shape, piece weight, spreading thickness, infeed temperature and target core temperature, calculated according to customer products, not written as a fixed value.

Structure and Configuration

The equipment is a continuous tunnel structure, composed of four parts: insulated enclosure, mesh belt conveying system, evaporator and cold air circulation system, and control system.

  • Insulated enclosure: inner and outer walls are formed from SUS304 food-grade stainless steel plate, with rigid polyurethane foam insulation layer in between to reduce cooling loss; the enclosure has access doors for cleaning and routine maintenance.
  • Mesh belt conveying system: stainless steel mesh belt with variable frequency speed control motor and tensioning device, conveying speed continuously adjustable, infeed and discharge ends can be connected with upstream and downstream processes.
  • Evaporator and cold air circulation: evaporator with axial flow fans and air guide plates, cold air circulates for heat exchange on both upper and lower sides of the mesh belt, allowing material surfaces to quickly pass through the ice crystal formation zone.
  • Control system: PLC plus touch screen control, PID automatic adjustment, temperature measurement using PT100 platinum resistance; with over-temperature alarm, emergency stop switch, grounding and phase sequence protection and other safety designs.

Applicable Scenarios

Scenario Description
Aquatic processing Continuous IQF of fish, shrimp, shellfish, requiring rapid passage through the ice crystal formation zone
Meat and poultry processing Continuous production lines for cut meat, poultry block freezing and IQF
Prepared dishes and prepared foods Multi-category switching, calling different mesh belt speeds and temperature programs according to product
Pastry and fruit/vegetable granular materials Continuous quick freezing of granular and small block materials

For batch-type, multi-variety small-batch production, cabinet equipment can be considered (liquid nitrogen quick freezing cabinet); for how to choose between liquid nitrogen refrigeration and mechanical refrigeration, see Comparison of Liquid Nitrogen Quick Freezing and Mechanical Refrigeration Quick Freezing.

Installation Conditions

  • Site: reserve space for operation, maintenance and infeed/discharge connection according to equipment external dimensions (external dimensions confirmed per order).
  • Power: 380V/50Hz, wiring and grounding according to total power and site power distribution capacity.
  • Heat dissipation: compressor condenser requires ventilation or cooling water conditions, the workshop should reserve heat dissipation space and maintenance access.
  • Floor and drainage: calculate floor load-bearing according to equipment fully loaded weight; the workshop should set slope and drainage ditches according to cleaning and drainage requirements.

Warranty and After-Sales

Whole machine warranty for one year; after receiving the request, a solution is provided within 2 hours, arrival on site within 24 hours, troubleshooting within 72 hours; one free on-site service per year, lifetime technical support.

Frequently Asked Questions

What does 1612 in DKN-RFT-1612 represent?

According to Kunning Cryo equipment numbering rules, the numeric segment for tunnel and mesh belt models is “mesh belt width (mm÷100) + mesh belt length (m)”, so 1612 means mesh belt width 1600 mm and mesh belt length 12 m. Mesh belt size determines the conveying surface of a line, not equal to hourly capacity.

Does this equipment use liquid nitrogen or a compressor?

It uses compressor refrigeration, i.e. mechanical refrigeration. Unlike liquid nitrogen quick freezing tunnels, it does not require a liquid nitrogen storage tank or low-temperature piping; it can operate once connected to power on site and with condensation and heat dissipation conditions in place, and operating costs are unrelated to liquid nitrogen prices.

How are capacity and freezing time calculated?

Piece weight, spreading thickness, infeed temperature, target core temperature and shift output requirements need to be provided, calculated according to specific materials; mesh belt speed is variable frequency adjustable, and freezing cycle can be adjusted with product. The parameter table does not list fixed hourly capacity precisely because capacity varies with material, and writing it as fixed would be misleading.

What are the working temperature, cooling capacity and total power?

These three items are configured according to customer materials, capacity and site power conditions; there are no fixed values in the technical data, confirmed per order. After working conditions are confirmed, we provide the corresponding selection parameters and power distribution requirements.

What discharge core temperature can be achieved?

Quick freezing conditions are calculated at material core temperature below -18℃; the specific achievable value is related to material thickness, moisture content, and residence time in the low-temperature zone, confirmed per order.

To verify the model according to material and capacity, you can go to Contact Us and provide piece weight, target core temperature and shift output requirements, and we will calculate according to parameters.