📞 +86 188 2550 1449 💬 WeChat / WhatsApp:18825501449 ✉ sales@kunningcryo.com

The cooling capacity of the freezing stage itself is fixed; what can actually be adjusted is how much heat and how much water the incoming material carries. When draining, tray spreading, and cooling are done properly, the incoming temperature and surface water film are both reduced, and the load on the freezing stage is lighter. When these three steps are skipped, the belt can only run slower, or the per-batch load must be reduced. In terms of sequence, drain first, then spread on trays, and only after tray spreading should cooling take place—reversing this is not recommended.

1. First, look at what the material brings in

The heat that freezing equipment must remove comes from three parts: the sensible heat of the material itself (from incoming temperature down to the freezing point), the latent heat of phase change (water turning to ice), and the excess water on the material surface and in the trays. The first two are determined by the process; the third is controllable on site.

More surface water carries a double cost: water releasing heat as it freezes is far greater than simple temperature reduction; at the same time, water in the freezing stage is first drawn out as frost, which deposits on the air passages on the evaporation side and on the belt wires, making the heat exchange conditions for each subsequent batch worse than the previous one. Juice pooling in trays that goes directly into the freezing stage means the equipment’s cooling capacity is spent freezing that layer of water first.

Common situation Extra load brought in What to do on site
Entering the freezing stage directly after washing, surface covered in water Surface water freezes first, bulk material cooling is delayed Let stand on draining racks, or blow off surface water with an air knife
Cut material with juice piled in trays Water pools at tray bottom and clumps, sticking to trays on discharge Spread on trays, tilt trays so juice runs off
Hot material just out of cooking/braising goes straight into the cabinet High incoming temperature, the first few tens of minutes are spent removing sensible heat Spread on trays and cool to process temperature before loading
Thawed raw material refrozen directly High drip loss, thick surface water film Drain well before spreading on trays

2. Draining and tray spreading: these two steps are the same task

The purpose of draining is to separate free water from the material surface and trays; the purpose of tray spreading is to give each piece an independent air-contact surface. When piled up, cold air only exchanges heat at the outer layer of the pile, and a center-temperature difference appears between the pile core and the pile edge.

The method is not complicated: after cutting, put the material on draining racks or a vibrating drainer so gravity carries surface water away; when loading trays, do not pile material into a cone—spread it flat, leave gaps between pieces, and tilt trays of juicy products slightly so juice collects in one corner rather than spreading across the bottom.

Tunnel lines require one more consideration: the belt runs continuously, and the spread thickness on the belt determines air permeability. Spread too thick, and the upper layer blocks the lower layer—the actual freezing time is calculated by the thicker layer. A more detailed calculation approach is given in Freezing cycle and belt speed of liquid nitrogen tunnels.

Tray spreading and draining before freezing

3. Cooling: hot material cannot go directly into the freezing stage

Material out of cooking, braising, or frying has a high temperature when removed from the pot, and going directly into the freezing stage has two consequences. First, the equipment’s cooling capacity is consumed by steam evaporating from the surface and by a large amount of sensible heat, so the early part of the cooling curve flattens noticeably; second, when hot material enters the low-temperature chamber, moisture in the chamber desublimates instantly, and frost forms much faster than with cold material.

The endpoint of cooling should not be judged by feel; set an incoming temperature upper limit according to the product’s process requirements, measure the center temperature in the cooling room or on the cooling rack, and load only when it is reached. The judgment method differs slightly between cabinet machines and tunnel lines:

Item Liquid nitrogen freezing cabinet DKN-LFC-1200 (four zones) Liquid nitrogen freezing tunnel line DKN-LFT-1212
Working temperature -150℃ ~ room temperature -150℃ ~ room temperature
Temperature control accuracy ±2℃ ±2℃
No-load pull-down ≤ 50℃/min 10℃ per minute
Loading/conveying 0~1200 kg per zone, with 10 racks Belt 12000 × 1200 mm, cycle 5~25 minutes adjustable
Total power 12 kW 18 kW
Power supply 380V wide voltage 380V/50Hz

Cabinet machines are batch-type; the rack temperature must be within range before pushing in, because one cabinet load runs for tens of minutes, and hot material mixed in will drag down the whole batch. Tunnel lines are continuous; temperature fluctuations at the feed end are masked for a while by belt speed, but they show up in the center temperature at the discharge end, so incoming temperature should be spot-checked per shift—not judged only by whether the belt is running smoothly.

4. Whether to add pre-chilling: look at two things

Pre-chilling is not a step every product needs. The basis for judgment is: is the material large in volume, and can the cooling room bring the center temperature down within an acceptable time?

  • No pre-chilling: small pieces, thin slices, cut material—air blowing in the cooling room is enough to reach incoming temperature, then go directly to the freezing stage; the flow is short.
  • Add pre-chilling: large cuts of meat, whole poultry, bone-in pieces—items whose centers cool slowly and cannot wait for natural convection in the cooling room. Use cold-air pre-chilling or cold-water pre-chilling to bring the center temperature down partway, then enter the freezing stage to complete the ice crystal zone. The pre-chilling stage temperature need not be very low; the goal is to reduce the temperature difference with the freezing stage, not to freeze the product.
  • Do not use pre-chilling to replace cooling: hot material going directly into a cold-air pre-chilling room forms a thin ice layer on the surface while the center is still releasing heat; this ice layer instead slows subsequent heat exchange.

For situations requiring continuous whole-batch pre-chilling, the immersion rapid cooler line is also worth considering; its cooling window logic is described in Cooling window of immersion rapid coolers. It is suited to cooked foods passing quickly through the danger temperature zone, which is not the same purpose as cooling before freezing.

5. Arranging sequence and rhythm

What easily goes wrong on site is rhythm mismatch: the cooling room is full while the freezing stage sits empty waiting for material, or conversely material pushes the equipment to run. A reasonable sequence is to plan in reverse: first set the feed rhythm of the freezing stage (batch-based for cabinet machines, belt speed and spread density for tunnel lines), then work backward to the incoming temperature upper limit, the number of trays to spread, and the cooling room capacity.

Step Judgment criterion Interface with the freezing stage
Draining No visible dripping on material surface, no pooled liquid at tray bottom Poor draining before tray spreading carries water into the freezing stage
Tray spreading Flat, gaps left, uniform thickness, juicy products tilted Spread thickness determines actual freezing time
Cooling Center temperature within process upper limit Spot-check per shift, return to cooling room if over limit
Pre-chilling (as needed) Center temperature enters the target range, no hard shell on surface A shell indicates excessive temperature difference; adjust pre-chilling temperature
Entering the freezing stage Load does not exceed equipment rated value Cabinet machine 0~1200 kg per zone; tunnel line matched to belt freezing throughput

Both the feed end and discharge end of the tunnel line have exhaust gas extraction ports connected to high-flow exhaust fans. When cooling and tray spreading are done well, the white mist at the feed and discharge ends is noticeably reduced, and the airflow at this section does not need to be constantly increased.

6. What is saved by these three steps

Draining, tray spreading, and cooling require no equipment investment—they depend on workstation arrangement and standard actions. Skipping them brings costs in three forms: longer freezing time (slower belt speed or longer in-cabinet circulation), higher liquid nitrogen consumption (the extra water being frozen), and defects at discharge (sticking, uneven color, high drip loss after thawing).

For workshops with many varieties and small batches, these three steps have an added benefit: after tray spreading, the piece count and placement on each tray are consistent, batch center temperatures are easier to equalize, and traceability records are easier to write. For the recording approach of the freezing process, refer to Temperature records and traceability of the freezing process.

For selection differences between cabinet machines and tunnel lines, and their respective loading methods, see the two product pages Liquid nitrogen freezing cabinet and Liquid nitrogen freezing tunnel line.

FAQ

To what temperature should material be cooled before it is ready?

Set an incoming temperature upper limit according to the product’s process requirements, and measure the center temperature, not the surface. Upper limits differ by category; specific values depend on product form and subsequent freezing time, and there is no universal value. The on-site practice is to spot-check several trays per shift and return over-limit trays to the cooling room—do not release them based on feel.

Can draining and tray spreading be combined into one operation?

Yes, but the actions should be viewed separately: draining relies on standing or vibration to separate water, and tray spreading relies on placement to give airflow a path. The same person can do both, but the order must not be reversed—spreading on trays before draining means water spreads across the tray bottom, equivalent to not draining at all.

What happens when hot material goes directly into a liquid nitrogen freezing cabinet?

Moisture in the chamber desublimates instantly, frost forms quickly, and it first accumulates at the door seal and the bottom water collection channel; at the same time, the equipment’s cooling capacity in the early stage is taken up by sensible heat and steam, lengthening the cooling time for the whole batch. The temperature control accuracy of the LFC-1200 is ±2℃, which means the chamber temperature is stable—not that it absorbs the heat of hot material for you.

Large white mist at the feed end of the tunnel line—is it caused by poor pretreatment?

In most cases, yes. Material with a lot of surface water and insufficient cooling lets low-temperature nitrogen spilling from the feed end carry water vapor, which appears as white mist. Check tray spreading and cooling first, then check whether the exhaust extraction port airflow is matched. Increasing airflow only extracts the white mist; the heat load remains in the equipment.

Can the freezing cabinet double as a pre-chilling stage?

Technically yes, but it is not cost-effective: the cooling capacity of the freezing cabinet is configured for passing through the ice crystal zone, so using it for pre-chilling is derated operation and also occupies a batch of capacity. Where pre-chilling volume is large, a separate cold-air pre-chilling room or cold-water pre-chilling section is smoother.

If you have specific material forms and shift output arrangements, go to Contact us and describe the product, piece weight, incoming temperature, and shifts clearly; we will check the equipment configuration against on-site conditions.