📞 +86 188 2550 1449 💬 WeChat / WhatsApp:18825501449 ✉ sales@kunningcryo.com

The output rhythm of the freezing section often gets stuck at the placement and transfer before entry, not at the freezing itself. Cabinet freezers run in batches: how much goes in at once and how the racks are layered directly determine the single-batch load and the handover to the next batch. Tunnel lines run continuously: whether the infeed is spread flat determines whether product piles up at the discharge end. This article separates four things: loading method, rack size verification, infeed/outfeed space, and workshop transfer.

Liquid nitrogen freezer cabinet loading and unloading

1. Three loading methods, chosen by product form

There is no good or bad loading method—only what fits the product form and packaging:

Loading method Suitable products Key control points
Tray spreading Cut meat, fish heads and fish pieces, IQF shrimp, prepared small items Spread thickness and tray spacing; products not stacked on each other
Rack and tray Semi-finished goods before boxing, bagged items, boxed items Rack layer height and load; tray material
Bulk onto mesh belt Granular, blocky, diced vegetables, fries Spreading width, feed uniformity, no ridges

For irregular IQF items such as fish heads, tray spreading is more common: one full layer, no pressing on each other, so the frozen shape stays intact and the product does not release water easily after thawing. Anything frozen in a pile tends to have problems with both appearance and core temperature.

2. Cabinet freezers: racks and single-batch load must match

Cabinet freezers run in batches: one batch in, one batch out. Take the four-zone DKN-LFC-1200 as an example: inner cavity 2000 mm × 1500 mm × 1750 mm, single-zone load 0–1200 kg, equipped with 10 racks, rack depth 1300 mm × width 1500 mm × height 1470 mm, two-layer structure.

Looking at these numbers together, two points need to be checked in advance:

  1. Clearance between rack outline and inner cavity. The rack width of 1500 mm matches the cavity depth of 1500 mm, so entry relies on guides and manual centering; it must be pushed in place in one go, and any offset will jam.
  2. Correspondence between single-zone load and rack load capacity. The 0–1200 kg per zone is an upper-limit figure; actual filling depends on product density and number of layers. For light bulky goods, fill by volume first; for dense goods, control by weight. Do not make one batch half light and half heavy, otherwise the cooling curves between zones will diverge.

The rhythm of a cabinet freezer is set by human-machine coordination: load, close door, start program, wait for completion, open door, unload. The point of four zones is that they can be used in staggered fashion—one batch cooling while the next is being loaded—so the number of racks must be enough for rotation; 10 racks for four zones leaves margin.

Freezer cabinet racks and transfer

3. Tunnel lines: spread flat at infeed, no blockage at outfeed

Tunnel lines run continuously: product travels the full length on the mesh belt and comes out, without stopping midway. The DKN-LFT-1206 has a mesh belt of 6000 mm × 1200 mm and an adjustable cycle from infeed to outfeed of 6–30 minutes; the DKN-LFT-1612 has a mesh belt of 12000 mm × 1600 mm and an adjustable cycle of 8–40 minutes, with a capacity figure of about 1000 kg/h (varying with product and packaging method).

An adjustable cycle means one machine can run different categories, but the loading section must be adjusted accordingly:

  • Feed spreading width should not exceed the effective belt width; leave edges on both sides so product does not run against the edge, otherwise it can catch in the chain edge.
  • Feed height should be below the infeed guard; piling it high carries air in, cold air spills at the infeed, and exhaust load rises.
  • Feed rhythm must match belt speed. If manual placement is uneven, dense and sparse sections appear on the belt; dense areas do not freeze through, and sparse areas waste liquid nitrogen.

The outfeed end of a tunnel line connects to packaging or transfer. If the downstream step is manual boxing, the outfeed should have a buffer table so frozen product does not land at the end of the belt waiting for someone to pick it up.

4. Infeed/outfeed space and workshop flow

The external dimensions of the equipment are just the machine itself; what really affects use is the space left at both ends for people and carts:

Location Space to leave Why
In front of cabinet door At least one rack length plus turning room in the rack pull-out direction Rack depth is 1300 mm; pulling out, turning around and pushing back in needs a flow path
Side of cabinet Service space on the electrical control cabinet side Cabinet doors can open fully; parameter adjustment without moving equipment
Tunnel infeed Loading table level with or slightly above the mesh belt Product is pushed onto the belt, not thrown
Tunnel outfeed Buffer table or transfer cart parking position Frozen product does not touch the floor or wait for people
Around equipment Exhaust duct routing decided in advance Exhaust fan discharge must connect to workshop exhaust

For transfer equipment, the wheels of carts, racks and turnover baskets must roll over workshop floor joints and ramps. Frozen product transfer favors speed: the shorter the door is open, the less cold air is lost. This is better considered together with exhaust in Workshop Ventilation and Noise Design.

5. Details that are easy to get wrong

  1. Tray material. Ordinary plastic trays become brittle at -150℃ and crack after a few cycles. Use stainless steel or dedicated low-temperature trays in low-temperature environments; wooden trays do not enter the freezing zone.
  2. Temperature band of the loading area. If the loading area is too close to the freezing zone, people stay in a low-temperature environment for long periods; if too far, product stays at room temperature too long and the core temperature has already risen before entry. Keep this distance within a few steps—do not cross workshops.
  3. Tray spread thickness and number of layers. For the same batch, tray spread thickness must be consistent, and the number of layers calculated according to rack layer height—do not add layers on the fly. When thickness is inconsistent, even ±2℃ temperature control accuracy cannot compensate; core temperatures at outfeed will vary.
  4. Frost and accumulated material. Racks and trays used at low temperature for long periods collect frost and ice chips; cleaning once per shift is easier than chipping it off after a week.
  5. Oxygen concentration in the loading area. Both cabinet freezers and tunnel lines are equipped with oxygen concentration detection, with a setpoint of 19.5%–21.5%; alarms interlock to cut off liquid nitrogen and start exhaust. The loading area is densely staffed and infeed/outfeed doors are often open; the location of detection points and alarm response in this area should be reviewed together—see the safety section after Hygienic Design and Material Selection for Freezing Equipment.

6. Loading differences between cabinet and tunnel

Comparison item Cabinet freezer (e.g. DKN-LFC-1200) Tunnel line (e.g. DKN-LFT-1612)
Material flow form Whole rack, whole batch Continuous mesh belt
Loading unit Rack, tray Spread single pieces or small trays
Rhythm control Programmed batches, human-machine coordination Belt variable frequency, loading rhythm matched
Transfer equipment Cart + rack Loading table + outfeed buffer table
Suitable scenario Multiple categories, small batches, high IQF shape requirements Single category, large batches, continuous output

Before choosing equipment, think through the loading section first: who places product, what container is used, how far it travels, how many people. Once these are settled, discuss the model—then the parameters will match. See Liquid Nitrogen Freezer Cabinet and Liquid Nitrogen Freezing Tunnel Line on the product pages.

FAQ

How much product can a rack hold at one time?

It depends on the model. The DKN-LFC-1200 has a single-zone load of 0–1200 kg, equipped with 10 racks in a two-layer structure. Actual load depends on product density and number of layers; for light bulky goods, fill by volume first; for dense goods, control by weight; keep the same batch as uniform as possible.

Does tunnel line loading have to be manual?

Not necessarily. When product form is regular and packaging is consistent, a loading machine or distribution device can be used; for irregular shapes that need to be separated for IQF, manual tray spreading is more stable. For manual loading, keep the loading table height level with the mesh belt to reduce bending and throwing.

How far should the loading area be from the equipment?

There is no fixed figure; the principle is within a few steps and within sight of the infeed/outfeed. Too far and product stays at room temperature longer, with core temperature rising; too close and staff stay in the low-temperature and nitrogen environment for long periods. In workshop layout, place the loading table, rack staging position and equipment infeed/outfeed on the same flow path.

Can frozen product be boxed directly after coming out of the tunnel?

Yes, but it depends on the packaging room temperature and dwell time. Set a buffer table at the outfeed first, spread the frozen product to release heat and remove surface frost, then pack. Stacking frozen product in boxes to wait, letting surface frost melt and refreeze, tends to cause clumping.

What is the difference between low-temperature trays and ordinary trays?

Mainly low-temperature flexibility. Ordinary plastic trays become brittle in deep-cold environments and crack when dropped or hit; stainless steel trays or trays made of dedicated low-temperature materials should be used in low-temperature environments; wooden trays do not enter the freezing zone.

How the loading and transfer section fits together depends on product, batch size and workshop layout. Send us the product form, single-batch weight and workshop floor plan, and we can review a layout together: Contact Us.